Enables scanning of files for Anti-Malware detection. Files which will be identified as infected will be deleted.

Image Removed

Anti-Malware Settings

1. Enable Anti-Malware - Set to 'Yes' in order to enable scanning for Anti-Malware detection.

    ** Need to restart the following back end components to apply modified settings: CASB Adapter service.

2. Internal domain list - List of local domain. Supports multiple  values and wildcards '*'.

3. Anti-Malware provider - Provider for Anti-Malware inspection. SphereShield uses CLAMAV open source.

    The other available option is McAfee.

4. Anti-Malware time out (in seconds) - Anti-Malware time out for waiting for response.

5. Service server - Server for ClamAV or McAfee server.

6. Service port - Port for ClamAV or McAfee server. Use 3310 for clamAV and 1344 for McAfee provider.

7. 

8. Admin notification type - Notifications sent to the administrator when a malware incident occurs.

   * Log - Log each incident to the log file , Windows Event log and database, or as defined in Log4Net configuration.

   * Log, Email and IM - Incident will be logged and recipient specified in the DLP settings will be notified by email.

     Image Removed

...

   * Log, Email - Incident will be logged, email notification will be send and the sender will be notified by IM.

   Image Removed

  1. Admin notification recipient (email)This field accepts a comma separated list of addresses for more than one recipient, Example: user@domain.com, user2@domain.com.
  2. Admin notification message (for IM & email)The following placeholders are available: {NEW_LINE},{USER},{RECIPIENT},{LOGGED_AT},{FILE_NAME}.
  3. Admin notification email subjectEmail subject for admin notifications.

9 . User notification type - Notification send to an end-user when a malware incident occurs.

   * None - No notification will be sent.

   * IM - Incident will be send to an end user by IM.

Image Removed

     User notification message -  Message sent to the use in case a malware incident was identified, but only a monitoring action was taken.

   * Email - Incident will be sent to and end-user by Email.

Anti-Virus ClamAV Installation and usage

ClamAV is a open source code that allows us to perform content scanning independently.

The code and its installation can be found at :https://www.clamav.net/downloads and windows version can be downloaded here: https://www.clamwin.com/content/view/18/46/

The Service

INSTALLATION: 

...

TCPSocket 3310
MaxThreads 2
LogFile c:\agat\Logs\clamd.log
DatabaseDirectory C:\Agat\clamav\database
TCPAddr 192.168.1.61 (OPTIONAL)
LogTime true (OPTIONAL)

...

DatabaseMirror database.clamav.net
DNSDatabaseInfo current.cvd.clamav.net
DatabaseDirectory "C:\Agat\clamav\database"
MaxAttempts 3
NotifyClamd C:\Agat\clamav\clamd.conf
LogFileMaxSize 20480000
LogTime true
UpdateLogFile C:\Agat\Logs\freshclam.log

...

Run the command: C:\(where the file-is located)\freshclam.exe --config-file c:\(Where-the-file-is-located)\freshclam.conf            **This command refreshes the antivirus database and is not a must.

...

** The following link should help in the installation process: http://kb.gtkc.net/installing-clamav-on-windows-server-2012.

The Program

INSTALLATION:

1 - Run the file: "clamav-0.99.2-x64.msi".
2 - Copy the folder "database" to the folder where the "clamscan.exe" placed (working directory).

USAGE:

1 - run the following command from the working directory: 

clamscan -r -l <file to write the result to> <file to scan>

E.G: "clamscan -r -l c:\Logs\scan_result.txt C:\virus_file.txt"

results:

Image Removed

Anti-Malware Auditing description

...

Enables scanning of files for Anti-Malware detection. Files which will be identified as infected will be deleted.

Image Added

Anti-Malware Settings

1. Enable Anti-Malware - Set to 'Yes' in order to enable scanning for Anti-Malware detection.

    ** Need to restart the following back end components to apply modified settings: CASB Adapter service.

2. Internal domain list - List of local domain. Supports multiple  values and wildcards '*'.

3. Anti-Malware provider - Provider for Anti-Malware inspection. SphereShield uses CLAMAV open source.

    The other available option is McAfee.

4. Anti-Malware time out (in seconds) - Anti-Malware time out for waiting for response.

5. Service server - Server for ClamAV or McAfee server.

6. Service port - Port for ClamAV or McAfee server. Use 3310 for clamAV and 1344 for McAfee provider.

7. 

8. Admin notification type - Notifications sent to the administrator when a malware incident occurs.

   * Log - Log each incident to the log file , Windows Event log and database, or as defined in Log4Net configuration.

   * Log, Email and IM - Incident will be logged and recipient specified in the DLP settings will be notified by email.

     Image Added

  1. Admin notification recipient (email) - This field accepts a comma-separated list of addresses for more than one recipient, Example: user@domain.com, user2@domain.com.
  2. Admin notification recipient (IM) This field accepts a comma separated list of addresses for more than one recipient, Example: user@domain.com, user2@domain.com.
  3. Admin notification message (for IM & email) - The following placeholders are available: {NEW_LINE},{USER},{RECIPIENT},{LOGGED_AT},{FILE_NAME}.
  4. Admin notification email subject - Email subject for admin notifications.

   * Log, Email - Incident will be logged, an email notification will be sent and the sender will be notified by IM.

   Image Added

  1. Admin notification recipient (email)This field accepts a comma separated list of addresses for more than one recipient, Example: user@domain.com, user2@domain.com.
  2. Admin notification message (for IM & email)The following placeholders are available: {NEW_LINE},{USER},{RECIPIENT},{LOGGED_AT},{FILE_NAME}.
  3. Admin notification email subjectEmail subject for admin notifications.

9 . User notification type - Notification sent to an end-user when a malware incident occurs.

   * None - No notification will be sent.

   * IM - Incident will be sent to an end user by IM.

Image Added

     User notification message -  Message sent to the user in case a malware incident was identified, but only a monitoring action was taken.

   * Email - Incident will be sent to and end-user by Email.


Auditing