SIEM Integration for Pragatix AI Security

SIEM Integration for Pragatix AI Security

Bring AI security insights into the SIEM your team already uses

Pragatix streams security, audit, AI Gateway, agent, Shadow AI, anomaly, health, and delivery events into your existing SIEM over one secure, standards-based feed. No new console to learn, no proprietary agent to deploy, no change to the workflows your analysts already trust.

Pragatix AI Security sends security, AI Gateway, agent, Shadow AI, anomaly, and health events over TLS-secured RFC 5424 syslog in JSON, CEF, or LEEF to your SIEM for search, dashboards, and alerts.

Validated SIEM platforms

These platforms were tested end to end against a live Pragatix deployment: events were delivered over TLS, parsed into fields, indexed, searched, and raised native alerts.

Graylog

Graylog Open 7.1

FULLY VALIDATED

Centralized search, dashboards, and alerting. Validated end to end with structured Pragatix events over TLS syslog, including retry and recovery.

Splunk

Splunk Enterprise 9.4.14

FULLY VALIDATED

Enterprise-scale security analytics. Validated through a syslog relay with a dedicated source type, indexed fields, dashboards, and alerts.

Wazuh

Wazuh 4.14.6

FULLY VALIDATED

Open-source security monitoring. Validated on a single-node deployment with a Pragatix decoder, indexed fields, search, and native alert rules.

Standards-based compatibility

Pragatix emits the industry formats these platforms already ingest, so they receive the same event stream through their standard syslog input.

IBM QRadar

IBM QRadar

LEEF COMPATIBLE

Receives Pragatix events in Log Event Extended Format over TLS-secured syslog.

OpenText ArcSight

OpenText ArcSight

CEF COMPATIBLE

Receives Pragatix events in Common Event Format over TLS-secured syslog.

LogRhythm

LogRhythm

CEF COMPATIBLE

Receives Pragatix events using standards-based CEF over RFC 5424 delivery.

These platforms support the required format and transport, and the serializers are validated. Native-console validation is not claimed, so a short interoperability test is recommended before production use. Any other RFC 5424, JSON, CEF, or LEEF receiver can be connected on the same basis.

Open standards. Secure delivery.

Secure transport

TLS-SECURED TCP

Events stay encrypted in transit from Pragatix to your SIEM, on port 6514 by default. Plaintext UDP is never used.

Standard delivery

RFC 5424 SYSLOG

The syslog standard your security tools, collectors, and relays already understand, with no custom connector to maintain.

Flexible formats

JSON / CEF / LEEF

Structured JSON for modern analytics, plus CEF and LEEF for established SIEM ecosystems. Choose per destination.

Which host sends the events

The feed is emitted by the Windows application server, the one running the Admin Centre and Core API. Events from the Linux components reach your SIEM through that same server, so there is one sender to allow, not several.

The firewall rule your network team needs is therefore:

Source

Destination

Port

Direction

Source

Destination

Port

Direction

Windows application server

Your SIEM collector

TCP 6514

Outbound from the Pragatix server

The complete firewall rule set for an on-premises deployment is on AI Security Suite POC Requirements (On-Prem).

What reaches your SIEM

One consistent event model covers the full picture of AI activity across your organization, and deliberately stops short of sensitive payloads.

Included in the event stream

  • Security and administrative audit events

  • AI Gateway activity and policy results

  • Agent and tool activity

  • Shadow AI detections

  • Security anomalies

  • Service health and exporter lifecycle

  • Delivery status for the feed itself

Never sent

  • Passwords and credentials

  • API tokens and secrets

  • Unrestricted prompt and response content

  • Tool arguments

  • Debug dumps

The feed carries audit metadata and policy results, so your SIEM gains full visibility without becoming a second copy of sensitive content.

Detail is configurable per destination. Warning, error, and critical security and health events are always available; informational service-health and lifecycle events are included only when Include operational information is enabled.

One SIEM, many environments and tenants

Every event carries the identity of where it came from, so a single SIEM can receive several Pragatix deployments and still keep them apart. Structured JSON events use schema version 1.1 and the stable schema ID ai_security.siem, and include the deployment ID, deployment name, environment type, product brand, product name, source host, and service name. Events owned by an account also carry the account ID and account name. CEF and LEEF carry the same identity fields.

That makes a cross-environment breakdown a single query:

Splunk: activity by deployment and tenant
index=main sourcetype="ai_security:siem:json" schema_id="ai_security.siem" | stats count by deployment_name account_name product_brand family severity

Because the deterministic event ID includes the immutable deployment ID, identical source records from different deployments never collide in your index.

Set it up in the Admin Centre

1. Open the page

Site administrators use Site Management > SIEM Integration. Account administrators with the Account Settings permission use Account Management > SIEM Integration.

2. Add a destination

Set the host, port, TLS server name, payload format, and severity filter. Site-wide destinations receive events from every account; account destinations receive only their own.

3. Send a test event

One click sends a warning-level audit event with a unique challenge ID, so transport, indexing, search, and alerting can all be confirmed in a single pass.

4. Watch delivery

Each destination reports successes over 24 hours and 7 days, failures and retries, pending count, oldest pending event, last success and failure, and TLS status.

You can configure up to three site-wide destinations and up to three destinations per account. Each one keeps its own format, severity filter, TLS server name, retry state, and duplicate-safe outbox, so a receiver going offline delays delivery rather than losing events.

Keep sender and receiver clocks synchronized with NTP, and allow a small clock-skew window in recipient alert rules.

Bring your own SIEM

You supply and license your SIEM infrastructure; Pragatix delivers the events in the format it already understands. Talk to your Pragatix contact about connecting a platform that is not listed here, or about a proof-of-concept interoperability test.